You have been redirected here from Daniels Electronics   |   Daniels Electronics is now Codan Radio

REAL TIME DATA

Codan Radio Communications now offers remote site monitoring options with live site data and logging capability for predictive trending.  These capabilities assist customers in responding promptly to potential communication emergencies.  Codan’s standard remote site monitoring kit includes all of the required equipment for most monitoring applications.  This kit includes sensor points on key operational lines of a Codan MT-4E repeater or remote base station as well as external sensors for monitoring temperature, enclosure entry, RF power output (Forward and Reverse) and AC or DC Power availability. 

MAXIMUM FLEXIBILITY

Add the remote site monitoring package to any Codan MT-4E series repeater or base station. Codan’s MT-4E series radios interface with the remote site monitoring onsite controller via direct wire line connections to analog and digital I/O available on the system subrack. Real-time and/or historical data collected at the site is passed onto a centrally-located PC equipped with APEX software via an existing radio (RF) link directly from the site or through an IP connection on a local area network (LAN). Codan Radio provides two separate remote site hardware solutions for customers interested in either communicating over RF links using the SiteCommander or over IP connections using the Summit.

View

SITECOMMANDER: RF LINK CONNECTIVITY

The SiteCommander is a low power, temperature-rated device that provides effective site monitoring and control at remote sites and is ideal in applications using RF links as the communications backhaul. When a site status check is required, an operator uses the APEX client software to initiate a call at a central base station site equipped with a Gateway SiteCommander. The base station polls the Remote SiteCommander sites using FFSK data signals sent over dedicated or shared RF links, which then returns site status information over these same RF links. The information is then displayed on any PC with APEX client software connected to the APEX Core Server.

SUMMIT: IP LINK CONNECTIVITY

The Summit is a powerful monitoring and control platform that offers a highly scalable I/O architecture. The Summit operates over Ethernet backhaul and can be sent over fiber, digital microwave, cellular (Fixed Stratus Infrastructure), or other IP solutions. The Summit controller interprets the signals produced by the external sensors, radio voltages, and control points, and generates event notifications. The event notifications are sent over IP (through a LAN) to a PC equipped with the APEX Client monitoring software. A software user can remotely control functions and devices at the remote site, such as transmitter Push-to-Talk (PTT) and security spotlights through the Summit web interface.

ANALOG AND P25 NETWORK INTEGRATION

Integrates into any analog or P25 network with complete communications interoperability

ANALOG AND P25 NETWORK INTEGRATION

PROVEN RUGGED DESIGN

Integrates into all MT-4E Series technology, the SiteCommander and Summit have the durability to survive in the harshest environmental conditions in the industry

PROVEN RUGGED DESIGN

EASY INSTALLATION

Directly replaces existing outdated hardware that utilizes V.24 interface. Cyclone is identical in size and design to existing products, ensuring product replacement is effortless

EASY INSTALLATION

NETWORK INTEGRATION

Integrates into any analog or P25 network with complete communications interoperability for instant expansion

NETWORK INTEGRATION

P25 INTEROPERABILITY

The open standard P25 interface ensures all P25 vendor subscribers are interoperable with the infrastructure equipment. Summit and SiteCommander can be interconnected to P25 infrastructure equipment, and the SiteCommander communicates RF over mixed mode P25 systems (in analog).

NETWORK INTEGRATION

Integrates into any analog or P25 network with complete communications interoperability for instant expansion

SCALABILITY

The SiteCommander and Summit can be configured for monitoring single or multiple radio systems and a wide array of external sensors.

FLEXIBILITY

SiteCommander operates at extremely low current at remote sites with only RF interconnect. Summit operates with enhanced functionality at sites with IP connectivity.

Remote Site Monitoring RF Solution

View

Remote Site Monitoring IP Solution

View

Controller Specifications

  • Controller

    Summit

    SiteCommander

  • Codan Application

    Monitoring over IP

    Monitoring over RF Link

  • Management Software

    APEX

    APEX

  • Mounting

    19" Rack (1RU)

    19" Rack (1RU)

  • Power

  • Input

    +8.0 VDC to +48.0 VDC

    +11.0 VDC to +20.0 VDC

  • Average current consumption

    250 mA @ +12.0 VDC

    60 mA @ +13.5 VDC
    (15 mA in sleep mode)

  • Operating Temperature

    -40.0 °C to +65.0 °C

    -40.0 °C to +65.0 °C

  • Interface

    10/100/1000 Base-T Ethernet

    1200/2400 bps FFSK over RF
    Gateway Interface via Ethernet or Serial

  • Digital Inputs

  • Number available (default)

    48

    8

  • Input Range

    0 VDC to +60.0 VDC

    0 VDC to +60.0 VDC

  • Supported Input Types

    Contact closure, switches, open collector, voltage inputs

    Contact closure, switches, open collector, voltage inputs

  • Digital Outputs

  • Number available (default)

    12

    8

  • Output Range

    Up to +50.0 VDC @ 150mA

    Up to +50.0 VDC @ 150mA

  • Supported Output Types

    Open Drain

    Open Drain

  • Analog Inputs

  • Number Available (default)

    32

    8

  • Input Range

    0 VDC to +25.0 VDC or 4mAto20mA
    16 bit resolution

    0 VDC to +5.0 VDC or
    0 VDC to +25.0 VDC or
    0 VDC to +100.0 VDC (external adapter) 8 x10bit A/D

  • Supported input types

  • Filters

    Hold time, threshold trigger set points per input, software defined qualifiers

    Hold time, threshold trigger set points per point

  • Analog Outputs

  • Number Available (default)

    4

    N/A

  • Output Range

    Up to +50.0 VDC @ 150 mA

    N/A

Sensor Specifications

  • Temperature Sensor (SiteCommander)

    Designed to monitor ambient temperature in an enclosed environment. RJ45 connection provides plug-in connection to the SiteCommander without using analog inputs

  • Application

    RF Link (SiteCommander) ONLY

  • Span

    -55 to +125°C

  • Accuracy

    -25 to +100°C ± 1.5 °C (nominal)

    -55 to +125°C ± 2 °C (nominal)

  • Current Draw

    2 mA per sensor

  • Temperature Sensor (Summit & SiteCommander)

    The Outdoor Temperatures Extended Reach Sensor detects outdoor ambient temperature which can be used over much longer leads than other temperature sensors (up to 100 feet) with the Summit or SiteCommander

  • Application

    IP (Summit) and RF Link (SiteCommander)

  • Span

    -40 to 49°C

  • Accuracy

    ± 1.5 °C

  • Operating relative humidity

    5% to 95% non-condensing

  • Cable length

    10 feet (3m); 50 feet (15m); 100 feet (30m)

  • Mounting

    Clip Included

  • DC Current Sensor

    The sensor/shunt combination is designed to measure DC current. Includes a Differential Voltage Sensor (also sold separately for voltage measurements that are not referenced to ground)

  • VDC In

    7 to 20 VDC

  • Current

    2 mA Max.

  • Operating Temp

    -40 to +65°C

  • +IN/-IN

    Differential Input Voltage = ± 0 – 125 mV Common Mode Voltage (CMV) = 0 – 65 VDC

  • AOUT

    0 – 5 VDC

  • Dimensions

    52 mm x 36 mm x 28mm (L x W x H)

  • Weight

    15 g

  • 100mV DC Ammeter Shunt

    5, 20, 30 or 50 AMP

  • AC Voltage Sensor

    The AC Voltage Sensor will measure AC voltage in a single phase system.

  • Environmental

    Functional temperature -25 to +70°C

  • Input

    0 –150 VAC, 0 – 300 VAC

  • Output

    0 – 5 VDC >1 kΩ

  • Enclosure

    Snap on to DIN rail 35 x 7.5 mm

  • Door Contact Sensor

    The sensor changes voltage when a magnet mounted near the sensor switch is moved away from or closer to the sensor switch

  • Loop Type

    Closed

  • Electrical Configuration

    Normally Open

  • Maximum Switching Voltage

    160 VDC

  • Maximum Switching Current

    0.4A

  • Cable Length

    50 feet (15 meters)
    100 feet (30.5 meters)
    150 feet (46 meters)

  • Maximum Gap

    1 1/4” (31.75 mm)

  • Bidirectional Power Sensor

    Bi-directional power monitor sensors provide a DC voltage output corresponding to an input RF signal. Provides precise forward and reflected power measurements

  • Bandwidth

    50 MHz

  • Frequency Range

    118-230 MHz
    380-512 MHz
    700-869 MHz
    806-960 MHz

  • Measurement Range

    5 W – 1000 W

  • Insertion Loss (typical)

    0.1 dB

  • VSWR

    1.1:1 Maximum

  • RF Connectors

    N Type

  • DC Connectors

    RCA-F standard

  • Impedance

    50 Ohms

  • Dimensions

    1.375 x 2.25 x 1.25 inches (3.5 x 5.7 x 3.2 cm)

  • Weight

    0.5 lb (0.2 kg)

  • Antenna and Cable Monitor

    Antenna and Cable Monitors are designed to detect antenna and cable faults that transmitter-internal VSWR monitors may not detect, and also provides accurate in-line power measurement functionality

  • VSWR

    1.07

  • Frequency Range

    136-225 MHz
    225-520 MHz
    470-960 MHz

  • Measurement Range

    2.5 W – 100 W or 12.5 W to 500 W

  • Insertion Loss

    0.1 dB

  • RF Connectors

    N Type

  • Alarm Set Point

    (1.3 to 2.5) to 1

  • Impedance

    50 Ohms

  • Reflected Directivity

    30 dB

  • Current Draw

    130 mA @ 13.8 Vdc

Software Specifications

  • Key Features

    • Event logging keeps track of incidents
    • Immediate notifi cation of alarm conditions
    • Real-time presentation by polling of operator selected data
    • Alarms can be sent to one or many operators
    • Visual, audible and pop-up alarm notification
    • Custom background map/graphics to suit your application
    • Permission levels settable to company defi ned security measures
    • Outputs at a given site can be “mapped” to change based on an event occurring at the same site or multiple sites

  • Server Core Requirements

  • Operating System

    Windows Server 2008 or higher-Recommended

  • Processor

    Intel Generation 3 (Minimum)

  • Memory

    4 GB RAM (Minimum)

  • Network Card

    10/100 Ethernet Card

  • Hard Drive

    500 MB free space-Recommended

  • Client Requirements

  • Operating System

    Windows XP/Vista/7/8/10

  • Processor

    Intel Generation 2 (Minimum)

  • Memory

    128 MB RAM

  • Network Card

    10/100 Ethernet Card

  • Hard Drive

    10 GB 7200 RPM, 20 MB free space

  • Resolution

    1024×768 (Minimum)

  • License Options

  • APEX

    10 simultaneous users; unlimited number of sites

  • APEX EMS